Reliable Cargo Measurement Starts with Honeywell HERMetic UTImeter GTEX N Series

Honeywell HERMetic UTImeter GTEX N Series – Portable Electronic Tank Gauging Equipment

 

The Honeywell HERMetic UTImeter GTEX N Series is a portable electronic level gauge developed for measuring liquid levels and temperatures in shipboard cargo tanks containing petroleum products and chemicals. It connects to a compatible HERMetic vapour-control valve to perform measurements within a closed system.

The instrument is designed to measure:

  • Ullage: Distance between the tank reference point and the liquid surface.
  • Temperature: Cargo temperature measurement using an integrated sensor.
  • Oil-water interface: Detection of the interface between oil and free water.
  • Innage/reference height: Measurement applications supported by the instrument and the applicable gauging arrangement.

The GTEX N Series uses an electronic sensor with audible indication and a graduated measuring tape. The backlit display provides readings for operational use, while the mechanical tape-cleaning device helps remove residual oil or chemicals during tape retraction.

Key Features and Benefits

  • Closed, gas-tight gauging: Supports measurement through compatible vapour-control valves, helping minimise the release of tank vapours.
  • Multi-parameter measurement: Combines ullage, temperature, and oil-water interface detection in one portable instrument.
  • Electronic sensor technology: Provides audible indication when the sensor detects the relevant tank medium.
  • High measurement accuracy: Published ullage and interface accuracy of ±2 mm, subject to the manufacturer’s specifications and applicable operating conditions.
  • Continuous temperature measurement: Supports cargo temperature verification during tank gauging.
  • Backlit LCD display: Improves readability during onboard measurement operations.
  • Mechanical tape-cleaning system: Helps clean the tape during retraction and supports routine equipment care.
  • Tape protection tube: Helps protect the tape and sensor assembly during valve operation.
  • Multiple tape lengths: Available in selected configurations from 15 m to 60 m, depending on the model.
  • Application-specific configurations: Standard, Chemical IIB, and Chemical IIC options support different liquid and chemical compatibility requirements.
  • Portable, battery-operated design: Allows gauging at compatible tank measurement points without a permanent electrical connection.

Available Versions and Model Selection

The HERMetic UTImeter GTEX N Series is offered in configurations suited to different cargo types and tank measurement requirements.

Standard version: Designed for use with non-corrosive liquids, subject to the manufacturer’s compatibility guidance.

Chemical IIB version: Intended for applications involving non-corrosive and corrosive liquids within the specified equipment compatibility limits.

Chemical IIC version: Intended for applications involving non-corrosive and highly corrosive liquids within the specified equipment compatibility limits.

Selected models are available with different tape lengths and sensor arrangements. Additional sensor loading may be recommended for high-viscosity products or particular innage measurements.

Technical Specifications

ParameterTechnical specification
Equipment typePortable electronic closed tank gauging instrument
ManufacturerHoneywell Tanksystem
Product seriesHERMetic UTImeter GTEX N
Measurement parametersUllage, temperature, oil-water interface and supported innage applications
Ullage/interface accuracy±2 mm
Tape accuracy±1.5 mm per 30 m
Tape resolution1 mm or 1/16 inch
Temperature accuracy±0.1°C from 0°C to 70°C
Temperature sensor range−40°C to +90°C
Temperature resolutionSelectable 0.01°C or 0.1°C
DisplayBacklit LCD, 8 characters
IndicationAudible and visible
Power supplyApproved 9 V batteries
Available tape lengths15 m, 25 m, 35 m, 50 m, 55 m and 60 m, depending on model
Maximum tank overpressure0.3 bar (4.4 psi)
Ambient operating temperature−20°C to +50°C

Get in Touch

Looking for HERMetic UTImeter GTEX N Series supply, installation, Calibration or service support?
Contact Swift Marine Tech Service for expert assistance, genuine products, and reliable marine solutions tailored to your vessel requirements in UK Region.

International Standards and Hazardous-Area Approvals

The manufacturer’s published product information identifies relevant standards and approvals for the HERMetic UTImeter GTEX N Series, including:

  • IMO SOLAS 1974 – International Convention for the Safety of Life at Sea.
  • MARPOL 73/78 – International Convention for the Prevention of Pollution from Ships.
  • API MPMS Chapter 3.1A – Manual gauging of petroleum and petroleum products.
  • API MPMS Chapter 7 – Temperature determination.
  • API MPMS Chapter 8.1 – Manual sampling of petroleum and petroleum products.
  • API MPMS Chapter 17.11 – Measurement and sampling of cargoes on marine tank vessels.
  • ISO 4512 – Petroleum and liquid petroleum products; equipment for measurement of liquid levels in storage tanks.
  • ISO 4268 – Petroleum and liquid petroleum products; temperature measurement.
  • ATEX and IECEx – Hazardous-area approvals applicable to the specified model and configuration.
  • Classification society and national approvals – Subject to the manufacturer’s published approval documentation.

We Are Here To Help You! 24*7

Contact Us >>

Service Type