The Honeywell HERMetic UTImeter GTEX N Series is a portable electronic level gauge developed for measuring liquid levels and temperatures in shipboard cargo tanks containing petroleum products and chemicals. It connects to a compatible HERMetic vapour-control valve to perform measurements within a closed system.
The instrument is designed to measure:
The GTEX N Series uses an electronic sensor with audible indication and a graduated measuring tape. The backlit display provides readings for operational use, while the mechanical tape-cleaning device helps remove residual oil or chemicals during tape retraction.
The HERMetic UTImeter GTEX N Series is offered in configurations suited to different cargo types and tank measurement requirements.
Standard version: Designed for use with non-corrosive liquids, subject to the manufacturer’s compatibility guidance.
Chemical IIB version: Intended for applications involving non-corrosive and corrosive liquids within the specified equipment compatibility limits.
Chemical IIC version: Intended for applications involving non-corrosive and highly corrosive liquids within the specified equipment compatibility limits.
Selected models are available with different tape lengths and sensor arrangements. Additional sensor loading may be recommended for high-viscosity products or particular innage measurements.
| Parameter | Technical specification |
|---|---|
| Equipment type | Portable electronic closed tank gauging instrument |
| Manufacturer | Honeywell Tanksystem |
| Product series | HERMetic UTImeter GTEX N |
| Measurement parameters | Ullage, temperature, oil-water interface and supported innage applications |
| Ullage/interface accuracy | ±2 mm |
| Tape accuracy | ±1.5 mm per 30 m |
| Tape resolution | 1 mm or 1/16 inch |
| Temperature accuracy | ±0.1°C from 0°C to 70°C |
| Temperature sensor range | −40°C to +90°C |
| Temperature resolution | Selectable 0.01°C or 0.1°C |
| Display | Backlit LCD, 8 characters |
| Indication | Audible and visible |
| Power supply | Approved 9 V batteries |
| Available tape lengths | 15 m, 25 m, 35 m, 50 m, 55 m and 60 m, depending on model |
| Maximum tank overpressure | 0.3 bar (4.4 psi) |
| Ambient operating temperature | −20°C to +50°C |
Looking for HERMetic UTImeter GTEX N Series supply, installation, Calibration or service support?